When the 1 hour smoke barrier is in a health care occupancy the ibc and nfpa 101 include an.
1 hour smoke barrier door requirements.
Two doors each with a fire protection rating of 1 hours installed on opposite sides of the same opening in a fire wall shall be deemed equivalent in fire protection rating to one 3 hour fire door.
4 3 2 1 1 2 3 3ยช 1 1 2 1 1 2 fire barriers having a required fire resistance rating of 1 hour.
This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings.
Doors in smoke barriers there are three use groups in the ibc that mention smoke barriers.
The primary difference between smoke barriers and smoke partitions originates from their required fire resistance ratings.
715 3 5 3 smoke and draft control door labeling requirements.
Louvers are not allowed in doors in smoke partitions.
The fire protection ratings of the protective openings on smoke barriers are required to be a minimum of 1 3 hour 20 minutes or at least a door that is 1 inches thick solid core door with.
1 1 1 smoke barriers 1 1 3b a.
Section 407 4 i 2 408 6 i 3 and 422 2.
Corridor walls that are required to be fire partitions with a 1 hour or hour rating other fire partitions with a hour rating and smoke barriers with a 1 hour rating.
For testing requirements see section 715 4 3.
The ibc mandates fire door assemblies with a 20 minute rating in 3 locations.
Smoke and draft control doors complying with ul 1784 shall be labeled in accordance with section 715 3 5 1 and shall show the letter s on the fire rating label of the door.
715 4 3 door assemblies in corridors and smoke barriers.
1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have.
For testing requirements see section 715 4 3.
Section 709 3 of the ibc establishes the requirement for smoke barriers to possess a 1 hour fire resistance rating.
Lation of smoke doors to be in accordance with nfpa 105 standard for the installation of smoke door assemblies and other opening protectives.
In existing health care occupancies the requirement is reduced to a half hour fire resistance rating.
Any penetrations of the smoke barrier must be sealed to maintain the fire resistance and to ensure that the barrier is relatively smoke tight.